banner

Knowledge

Home>Knowledge

How to Troubleshoot Unstable Sealing Pressure of Sealing Robot Machine

2026-07-28 14:34:02

封胶线细节5 - 副本

If your sealing robot machine shows unstable sealing pressure (fluctuating high and low pressure), you can troubleshoot it as follows.

First, observe the pressure gauge. The real-time working pressure will be clearly displayed during sealing. Our sealing robot machine adopts a hydraulic system, where the proportional valve is the core component that directly controls the sealant output pressure.

This valve has extremely fine internal holes, which require clean hydraulic oil to avoid valve jamming and pressure fluctuation. During factory assembly, the entire hydraulic station is thoroughly cleaned, and the hydraulic oil passes through two precision filtration processes before entering the proportional valve, ensuring stable factory-outlet performance.

In actual after-sales cases, most pressure instability problems are caused by unqualified fake 46# anti-wear hydraulic oil. Substandard oil contains sticky impurities that block the precision valve holes, resulting in irregular high and low pressure.

Solution: Always use genuine 46# anti-wear hydraulic oil from reputable brands. This single standard can solve most pressure fluctuation failures of the sealing robot machine.

We are producing IGU lines, Insulating Glass Machine, Insulating Glass Argon Gas Filling Line, Insulating Glass Sealing Robot Line and all kinds of Special-Shaped Glass Sealing Robot, Insulated Glass household appliances with wire sealing machine. We have our own technology to supply you Customizable IGU machines and lines.


If you want to know more about our insulating glass machine line, welcome to subscribe to our YouTube channel